Mist filters: How steady is their "steady state"?

Kolb, HE; Kasper, G

Kolb, HE (reprint author), Donaldson Europe Bvba, Res Pk Zone 1,Interleuvenlaan 1, B-3001 Leuven, Belgium.

CHEMICAL ENGINEERING SCIENCE, 2019; 204 (): 118

Abstract

This paper addresses the phenomenon of a slow Delta p increase ("creep") sometimes observed in mist filters during their so-called steady-state operat......

Full Text Link